Storage And Drying Parameter Table For E6013 Electrodes
Send Inquiry
Product Introduction
| Electrode Status | Storage Requirements | Drying Parameters | Cooling Requirements | Applicable Scenarios |
|---|---|---|---|---|
| Undampened (new electrodes) | 1. Ambient temperature: 15-30℃ 2. Relative humidity: ≤60% 3. Storage method: Sealed moisture-proof packaging, ≥10cm above ground |
No drying required | - | Newly purchased electrodes, used within ≤3 months |
| Slightly damp | Slight packaging damage, no obvious rust/moisture traces on electrode surface | Temperature: 70-90℃, Time: 1h | Cool to room temperature (20-25℃) before use | Occasional humidity exceeding standards (60%-70%) in storage environment |
| Moderately damp | Small amount of frost-like moisture on surface, no coating cracking | Temperature: 110-130℃, Time: 1.5h | Cool to 50-60℃ then place in insulation cylinder (temperature ≥80℃) | Stored for >6 months or severely damaged packaging |
| Severely damp | Coating cracking/peeling, or rust on electrode surface | Temperature: 140-150℃, Time: 2h | Cool to 50-60℃ then use immediately; no secondary storage | Long-term exposure to high humidity (>85%) |
| Special storage | For long-term storage (>12 months) | Dry at 100℃ for 1h before storage, then seal in vacuum packaging | No re-drying needed if vacuum packaging is intact | Overstocked inventory or cross-season storage |